What is new in EC-Lab® V10.0


NEW FEATURES

  • New 3-D graphic representation available off-line

3D plot

  • New corrosion techniques and dedicated analysis tools
    • Variable Amplitude Sinusoidal microPolarization (VASP) and dedicated analysis tool VASP fit VASP icon

EC-Lab V10.0 news_clip_image002_0001
EC-Lab V10.0 news_clip_image004

 

EC-Lab V10.0 news_clip_image006

    • Constant Amplitude Sinusoidal microPolarization (CASP) and dedicated analysis tool CASP fitCASP icon

EC-Lab V10.0 news_clip_image002_0003EC-Lab V10.0 news_clip_image003

EC-Lab V10.0 news_clip_image005

 

These techniques (CASP and VASP) with their linked analysis tools (CASP fit and VASP fit) allow the determination of Icorr and of the corrosion coefficients faster than using a standard Linear Polarization followed by a Tafel fit.

  • New analysis tools

Corr Sim EC-Lab V10.0 news_clip_image002_0004 for simulating corrosion curves
EC-Lab V10.0 news_clip_image004

Electrochemical Noise Analysis (ENA) EC-Lab V10.0 news_clip_image006_0000
EC-Lab V10.0 news_clip_image008

 

Fourier transform (FT)
EC-Lab V10.0 news_clip_image012

 

Linear interpolation EC-Lab V10.0 news_clip_image014
EC-Lab V10.0 news_clip_image016

Files subtraction EC-Lab V10.0 news_clip_image018EC-Lab V10.0 news_clip_image020

Filter EC-Lab V10.0 news_clip_image022 (many methods available (moving average, Savitzky-Golay, low pass, high pass, band reject and band pass)).
EC-Lab V10.0 news_clip_image024
This filter can be used off-line or applied automatically simultaneously at the end of experiments.

  • Support of the SP-50 single channel potentiostat added
  • Support of the MPG2 16-channel potentiostat (fixed configuration) added

IMPROVEMENTS

  • Advanced parameters and Cell characteristics windows are now localized in the right side of EC-Lab® main window just before the Parameters Settings window.

Advanced Settings

  • Math menu doesn't exist anymore, it is now included in the Analysis menu. Tools in this Analysis menu are classified depending on the applications: battery, corrosion, EIS, ...
  • E Range selection is now included in the technique in the continuity of the other parameters and no more in the top of the window.

ERROR CORRECTIONS

  • A flash error occurred for the VM42 communication board of VMP1 instruments since version 9.94.
  • Percentage of compensation in ZIR technique was not properly calculated.